Technical Specifications
Video and Audio Technology
Technology Components
- Three Polycom HDX 9004 video codecs supporting 720p at 30 fps
- Two Polycom Digital Ceiling Microphone Arrays
- Polycom StereoSurround Speaker Kit
- Three 60-inch Plasma Displays
- Three High Definition Video Cameras
- Room control system with 6 inch color touch panel
- Content Monitor (Optional)
- 50 inch plasma on a Polycom Executive Collection Stand
Video Standards
- H.261
- H.263++
- H.264
- H.239 People+Content
- H.263 and H.264 Video Error Concealment
- AES Media Encryption for secure video/audio and content
Audio Standards
- 22 kHz bandwidth with StereoSurround Siren 22
- 14 kHz bandwidth with Polycom Siren 14, G.722.1 Annex C
- 7 kHz bandwidth with G.722, G.722.1
Connectivity
Call Modes
- TelePresence to TelePresence point-to-point
- face to face, 6 seats in real size
- Traditional Video Conferencing
- Remote view in main display
- Main camera shows all participants in "TelePresence 6" room
- Various multipoint modes per application and bridging capabilities
Network and Analog Line Requirements
- 4 Ethernet 100 Base-T for network connectivity
- Video network requirements to support 720p high definition (including dedicated video bandwidth and overhead):
- Minimum Bandwidth for HD in TelePresence Mode (3 screens): 7.5 Mbps
- Recommended Bandwidth for HD in TelePresence Mode in maximum performance (3 screens): 15 Mbps
- Compatible with Video Conferencing call rates from 128 kbps to 4Mbps (1 screen)
- One Analog phone line for integrated Audio Add-On
Polycom TPX HD 306M Room Environment
Seating Capacity
- Six seats on-camera
- For off-the-call use (non-TelePresence /non-video conferencing) accommodates 12 seats
Room Size and Floor Layout
- Minimum room size:
- 18ft Width x 13ft Depth
- 5.5m Width x 4m Depth
- Recommended room size:
- 24ft Width x 15ft Depth
- 7.3m Width x 4.5m Depth
Power and Cooling
- The following data assumes the room is at full occupancy and all equipment is turned on and there is an active call in progress.
- Total Power Required (Watts): 2500 watts
- BTUs/Hour: 13,000
- Cooling in Ton: ~1.1 cooling tons
Environmental Conditions
- Conference Room Operating Temperature: 41-86 F, 5-30 C
- Relative Humidity : 10% to 95% (non-condensing)
Total Installed Weight
- Front wall credenza total weight is approximately 1760 pounds (798.3 kg), covering approximately 40 square feet (3.716 square meters)
- Telepresence table total weight is approximately 695 pounds (315.3 kg), covering approximately 60 square feet (5.57 square meters)
Regulatory Compliance
Collapse [-]